Expand your X-CPU-2. The ABC X-EXT-2/6 Extension board can be plugged directly into their X- CPU-2/6.
With this card, you can expand their plant/system with modern fieldbus components or modernize the existing structure.
There are possible up to 3 fieldbus master: Profibus, Profinet, EtherCAT
The integration of your fieldbus components in the STEP5/7 project assumes the X-CPU-2/6. These are displayed as normal peripheral in STEP5/7 program and automatically updated by the process image.
| Bus Interface | Mini PCI-Express over adaptation board |
| Electrical Data | 3,3V / 650mA |
| Operating Temperature | 0°C … 55°C |
| Dimensions (L x W x H) | 167 x 109 x 10 mm |
| Slaves max. | 125 |
| Cyclic Data max. | 7168 Bytes |
| DPV1 class 1,2 | yes |
| Configuration Data | 244 Bytes/Slave |
| Application Spec. Parameters | 237 Bytes/Slave |
| Cyclin Data max. | 488 Bytes (IOCR) |
| DPV1 class 1,2 | yes |
| Configuration Data | 244 Byte |
| Application Spec. Parameters | 237 Bytes |
| Transmission Rate | 9,6 kBaud to 12 Mbaud |
| Controller | netX 100 |
| Interface | RS485, floating |
| Plug Connector | DSub 9 |
| Indication | SYS, COM |
| Cyclic Data | max. 11520 Bytes |
| Acyclic Data | CoE (CAN over EtherCAT) |
| Features | Emergency |
| Get OD List | |
| Topologie: line |
| Cyclic Data | max. 400 Bytes |
| Acyclic Data | SDO Master/Slave |
| SDO Slave/Slave | |
| Features | 3 FMMUs and 4 SYNC-Manage |
| COE (CANopen over Ethernet) | |
| Complex slave | |
| Emergency |
| Transmission Rate | 100BASE-TX, IEEE 1588 time stamp |
| Data-Transport-Layer | Ethernet II, IEEE 802.3 |
| Controller | netX 100 |
| Plug Connector | 2x RJ45 Socket by AIFX-RE |
| Indication | SYS, RUN, ERR |
| Cyclic Data | max. 6144 Bytes |
| Acyclic Data | Read/Write Record, max. 4096 Bytes/Request |
| Features | Alarm handling |
| Context Management over CLRPC | |
| DCP | |
| max. 32 Devices | |
| min. cyclic time 1 ms | |
| per device one buffer for diagnostic data available |
| RTC – Real Time Cyclic Protocol, class 1 | |
| RTA – Real Time Acyclic Protocol | |
| DCP – Discovery and configuration Protocol | |
| CL-RPC – Connectionless Remote Procedure Call |
| Cyclic Data | max. 2048 Bytes (IOCR) |
| Acyclic Data | Read/Write Record, max. 1024 Bytes/telegram |
| Features | Context Management over CLRPC |
| DCP | |
| Process and diagnostic alarm | |
| 1 Submodul | |
| Diagnose, max. 200 Bytes/telegram | |
| max. 244 modules | |
| Soll/Ist-Vergleich der Konfiguration | |
| VLAN- and Priority-Tagging |
| Transmission Rate | 100BASE-TX, IEEE 1588 time stamp |
| Data-Transport-Layer | Ethernet II, IEEE 802.3 |
| Controller | netX 100 |
| Plug Connector | 2x RJ45 Socket |
| Indication | SYS, SF, BF |
Description |
Order Number |
Price |
| ABC X-EXT-2/6 Extensionboard | 100-1210-10 | On request |
| Profibus Master for X-EXT-2/6 Extensionboard | 100-1210-20 | On request |
| Profinet Master for X-EXT-2/6 Extensionboard | 100-1210-30 | On request |
| EtherCAT Master for X-EXT-2/6 Extensionboard | 100-1210-40 | On request |